        Home > News&Events > Company news > How to prolong the service life of electrolytic antimony equipment?
        Latest News
        Its main purpose is to collect the high-temperature flue gas rich in Sb?O? that volatilizes from the smelting furnace...
        2025.11.12
        Choosing mature solvent extraction-electrowinning technology and reliable copper extraction equipment is undoubtedly a key step in achieving efficient resource conversion and maximizing economic value...
        2025.11.12
        In the copper sulfide ore smelting process, the anode casting step is crucial...
        2025.11.11
        Exploring key auxiliary processes in scrap copper smelting..
        2025.11.11
        This document details the electrolytic refining process of scrap copper in an electrolytic cell...
        2025.11.10

        How to prolong the service life of electrolytic antimony equipment?

        Release time:2025-05-29 09:10 Views:

        To extend the service life of electrolytic antimony equipment, it is necessary to start from maintenance, operation, materials, fault prevention and other aspects. The specific measures are as follows:

        Electrolytic antimony equipment

        I. Regular maintenance and care

        1. Cleaning and inspection: Clean the dust and debris on the surface and inside of the equipment daily, wipe the outer shell with a suitable detergent and dry it; check whether the power cord, switch and other components are intact and function normally before each use.

        2. Maintenance of core components: Regularly clean the scale and crystallization of the electrolytic cell, replace the electrolyte; check the cable connection and insulation layer, maintain the power supply equipment, and clean the radiator.

        3. Replacement of wearing parts: Regularly replace the filter element, belt, seal, etc., and establish a replacement record to track the service life.

        II. Optimize operation management

        1. Accurate control of parameters: Maintain the electrolyte Sb3? concentration at 50-80g/L, the temperature is stable at 40-60℃, and reasonably set the current density (such as 200-400A/m2).

        2. Standardize the operation process: first turn on the power switch, adjust the current stabilizer, then prepare the solution and the tank cleaning solution. It is strictly forbidden to operate with wet hands; the operator wears acid-proof clothing and goggles, and the workshop is equipped with emergency flushing and ventilation equipment.

        III. Material selection and optimization

        1. Corrosion-resistant material: Select an electrolytic cell lined with polyvinyl chloride, and the electrode uses copper sheets and other corrosion-resistant and conductive materials.

        2. Diaphragm material upgrade: Use new diaphragm materials such as nano-ceramic coating to improve corrosion resistance and reduce replacement frequency.

        IV. Fault prevention and handling

        1. Common fault prevention: Install a real-time current monitoring system, regularly check the power supply equipment and lines; set up temperature sensors and cooling water circulation systems; select suitable electrode materials and establish replacement records; install automatic stirring devices, and regularly analyze the electrolyte concentration.

        2. Quick fault handling: Check the power supply, electrode and other factors when there is no current; establish equipment files and formulate inspection and maintenance plans.

        V. Storage and environmental protection

        1. Storage conditions: Long-term storage equipment should be placed in a dry and ventilated place to avoid direct sunlight.

        2. Environmental protection measures: Equipped with waste liquid treatment system, using environmentally friendly agents and wastewater reuse technology.

        By implementing the above measures, the life of electrolytic antimony equipment can be significantly extended, operation and maintenance costs can be reduced, and production efficiency can be improved. Enterprises should formulate personalized maintenance plans based on their own equipment characteristics and process requirements, and continuously optimize operating procedures and management systems.


        主站蜘蛛池模板: 欧美丰满熟妇乱XXXXX网站| 亚洲国产精品成人av网| 亚洲欧美日韩第一页| 欧洲熟妇色xxxx欧美老妇免费| 国产精品老熟女乱一区二区| 久青草国产在视频在线观看| 99久久国产宗和精品1上映 | 亚洲无人区一区二区三区| 乱女乱妇熟女熟妇综合网| 国产精品一区在线免费看| 99久久国产露脸国语对白| 国产精品爽爽久久久久久| 兴和县| 免费无码午夜理论电影| 久久老熟女一区二区蜜臀| 1区2区3区高清视频| 国内揄拍国内精品人妻久久| 精品亚洲国产成人| 国产精品一区二区三区色| 强奷乱码欧妇女中文字幕熟女| 国产精品久久久久久妇女| 国产亚洲精品在av| 亚洲欧洲日韩精品在线| 老子午夜精品无码| 国产高在线精品亚洲三区| 久久精品不卡一区二区| 大香伊蕉在人线国产av| 亚洲日韩AV秘 无码一区二区| 亚洲中文字幕在线精品一区| 99久久精品久久久久久婷婷| 亚洲国产精品无码久久久| 熟女少妇精品一区二区| 欧美午夜理伦三级在线观看| 国产高清在线a视频大全 | 欧美午夜精品久久久久久浪潮| 九九久久精品国产免费看小说| 亚洲高清日韩专区精品| 亚洲天堂av免费在线看| 国产精品视频亚洲二区| 综合偷自拍亚洲乱中文字幕| 无码精品人妻一区二区三区中|